ATM90E Power Energy Monitor Boards Comparison

ParametricsATM90E26
GTEM
ATM90E32
IPEM
ATM90E36
IPEM
Active Energy Accy (%)0.10.10.1
ADC Channels367
ADC Resolution (bits)161616
Board PSU Operating Voltage Range (AC RMS)5 to 20 V5 to 20 V5 to 20 V
Crystal Frequency (ATM)8.192 MHz16.384 MHz16.384 MHz
Current Monitoring Channels134
Current Range (RMS)0 to 65.535 A0 to 65.535 A0 to 65.535 A
Data Dumping over DMA (SPI-Master)--Yes
Direct Memory Access (DMA)--Yes
Discrete Fourier Transform (DFT) Function--Yes
Dynamic Range5000:16000:16000:1
Energy Metering Analog Front-End Channels367
Enhanced Poly-Phase High-Performance-YesYes
ESP32 ATM90 Default InterfaceSPISPISPI
ESP32 BT Frequency Range2402 MHz to 2480 MHz2402 MHz to 2480 MHz2402 MHz to 2480 MHz
ESP32 External UART2 Interface-YesYes
ESP32 WLAN Frequency Range2412 MHz to 2462 MHz2412 MHz to 2462 MHz2412 MHz to 2462 MHz
Frequency Detection Range45 to 65 Hz45 to 65 Hz45 to 65 Hz
Increased Functionality--Yes
LED/GPO ActiveYesYesYes
LED/GPO Harmonic -YesYes
LED/GPO ReActiveYesYesYes
LED/GPO Fundamental-YesYes
Low Temperature Drift-YesYes
Mean Power Monitoring-YesYes
Meter TypeSingle PhaseThree Phase (3P3W, Y or Δ)Three Phase (3P3W, Y or Δ)
Operating Ambient Temperature Range–40°C to +85°C–40°C to +85°C–40°C to +85°C
Operating Ambient Temperature Range 24C64–40°C to +85°C–40°C to +85°C–40°C to +85°C
Operating Ambient Temperature Range ESP32–40°C to +125°C–40°C to +125°C–40°C to +125°C
Operating Ambient Temperature Range SMPS–40°C to +85°C–40°C to +85°C–40°C to +85°C
Operating Ambient Temperature Range UART–40°C to +85°C–40°C to +85°C–40°C to +85°C
Operating Voltage - Board AC RMS8 to 12V8 to 12V8 to 12V
Parameter Diagnosis Function--Yes
Power Factor Range-1.00 to +1.00-1.00 to +1.00-1.00 to +1.00
Reactive Energy Accy (%)0.20.20.2
Sag DetectionYesYesYes
Single Point CalibrationYesN/AN/A
Temp Coefficient Type (ppm/degC)1566
Total Harmonic Distortion (THD) Function Current--Yes
Total Harmonic Distortion (THD) Function Voltage--Yes
UART PortYes--
Voltage Monitoring Channels1 Line3 Line3 Line + 1 (Neutral)
Voltage Range (RMS)0 to 655.35 V0 to 655.35 V0 to 655.35 V
Voltage Sensor Inputs ATM Maximum (AC RMS)20 V20 V20 V