{"product_id":"ipem-plus-atm90e36-esp32c5-sx1262-lora-wi-fi-iot-remote-mains-power-energy-monitor","title":"IPEM Plus ATM90E36 ESP32C5 SX1262 LoRa Wi-Fi IoT Remote Mains Power Energy Monitor","description":"\u003cp dir=\"auto\"\u003e\u003cstrong\u003eIPEM Plus\u003c\/strong\u003e is a powerful ATM90E36 REMOTE Smart Home and Industry Automation Board, and Kit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"auto\"\u003eSelf-contained ESP32-C5 based IoT monitoring board. Ideal for local, or remoting, monitoring requirements.\u003c\/li\u003e\n\u003cli dir=\"auto\"\u003eProvides easy connectivity to Wi-Fi connections, 2.4GHz or 5GHz, plus Bluetooth, Thread and Zigbee. In addition, you may also use the inbuilt LoRa Radio IoT 850 MHz through to 930 MHz\u003c\/li\u003e\n\u003cli dir=\"auto\"\u003eHas been designed to easily monitor, and offer a flexible interface too, a whole range mains power energy installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/github.com\/DitroniX\/DitroniX\/blob\/main\/Compare%20Mains%20Power%20Energy%20Monitors.md\" title=\"DitroniX Mains Power Polyphase IoT Energy Monitor Comparisons\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0972\/8507\/9368\/files\/Compare-DitroniX-Energy-Monitors-1024x106.png?v=1782664552\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eHome | Industry | Housing | Educational | Farming | Agriculture | Solar | Energy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eUsing its 2.4GHz and 5GHz Wi-Fi, Thread and Zigbee ESP32-C5 radio module, you can use the \u003cstrong\u003eIPEM Plus\u003c\/strong\u003e to connect ta whole range of Smart Monitoring applications and projects.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eExtending further, the built-in LoRa radio opens up long range and remote monitoring.\u003c\/p\u003e\n\u003ch3 class=\"heading-element\" dir=\"auto\" tabindex=\"-1\"\u003eIPEM Continuity\u003c\/h3\u003e\n\u003cdiv class=\"markdown-heading\" dir=\"auto\"\u003e\n\u003cp\u003eFollowing in the footsteps of the original popular \u003ca href=\"https:\/\/github.com\/DitroniX\/IPEM-IoT-Power-Energy-Monitor\"\u003eIPEM boards\u003c\/a\u003e, this \u003cstrong\u003eIPEM Plus\u003c\/strong\u003e is the latest in IoT Mains Energy Monitoring for Home and Industry Automation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eIPEM Plus\u003c\/strong\u003e is the replacement to the original \u003ca href=\"https:\/\/github.com\/DitroniX\/IPEM-IoT-Power-Energy-Monitor\"\u003eIPEM boards\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 class=\"heading-element\" dir=\"auto\" tabindex=\"-1\"\u003eCompare Energy Monitors\u003c\/h3\u003e\n\u003cp\u003eThis \u003ca href=\"https:\/\/github.com\/DitroniX\/DitroniX\/blob\/main\/Compare%20Mains%20Power%20Energy%20Monitors.md\" rel=\"noopener\" target=\"_blank\"\u003etable\u003c\/a\u003e compares the different DitroniX Power Energy Monitors.\u003c\/p\u003e\n\u003ch3\u003eInformation and Wiki\u003c\/h3\u003e\n\u003cp\u003eFull information and \u003ca href=\"https:\/\/github.com\/DitroniX\/IPEM-Plus-ESP32-C5-LoRa-LoRaWAN-IoT-Mains-Power-Energy-Monitor\/wiki\" rel=\"noopener\" target=\"_blank\"\u003eWiki\u003c\/a\u003e is available on the \u003ca href=\"https:\/\/github.com\/DitroniX\/IPEM-Plus-ESP32-C5-LoRa-LoRaWAN-IoT-Mains-Power-Energy-Monitor\" rel=\"noopener\" target=\"_blank\"\u003eDitroniX GitHub pages\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"markdown-heading\" dir=\"auto\"\u003e\n\u003ch3 class=\"heading-element\" dir=\"auto\" tabindex=\"-1\"\u003eCurrent Monitoring and Interfaces\u003c\/h3\u003e\n\u003cp\u003eExpanding the mains current sensors, either CT Clamps, or Rogowski Current Transformers, maybe connected. This allows for \u003cstrong\u003eIPEM Plus\u003c\/strong\u003e to be used for both lower current Home systems and Industrial or commercial installations, which require higher current monitoring in hundreds of Amps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eThe accurate \u003cstrong\u003e\u003ca href=\"https:\/\/ww1.microchip.com\/downloads\/en\/DeviceDoc\/Atmel-46004-SE-M90E36A-Datasheet.pdf\" rel=\"nofollow\"\u003eAtmel ATM90E36\u003c\/a\u003e\u003c\/strong\u003e is used for Enhanced Poly-Phase High-Performance Wide-Span Energy Metering, with fast SPI data communications to an Espressif \u003cstrong\u003eESP32-C5 MCU\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eThe board can \u003cstrong\u003esafely monitor a range of mains AC circuits\u003c\/strong\u003e, from Single phase, Split or Dual phase (such as USA), and both types of Three phase, Star and Delta. Full 50 Hz and 60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eAn onboard accurate \u003cstrong\u003e16bit ADC\u003c\/strong\u003e allows for monitoring of DC voltages up to 80V.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eRS485\u003c\/strong\u003e port allows interfacing to other local or remote sensors and monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eAccurate \u003cstrong\u003eReal Time Clock\u003c\/strong\u003e DS3231SN, with Battery Backup Option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eA \u003cstrong\u003egalvanically isolated OPTO output\u003c\/strong\u003e can be used to safely connect or drive a range of external systems or devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eTwo \u003cstrong\u003eexpansion ports\u003c\/strong\u003e, SPI and I2C, facilitate an optional display panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eMicroSD card\u003c\/strong\u003e, for buffering or logging data. This is mounted in the display panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eThe IPEM Plus has been designed to be compact, with an option to fit into a \u003cstrong\u003eDIN enclosure\u003c\/strong\u003e, for cabinet or rack installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"markdown-heading\" dir=\"auto\"\u003e\n\u003ch3 class=\"heading-element\" dir=\"auto\" tabindex=\"-1\"\u003eSafety First\u003c\/h3\u003e\n\u003cp\u003eAs with all our boards, safety is paramount, with AC sensing being from lower voltage inputs, through galvanically isolated mains transformers. Examples are bell transformers. This allows the IPEM Plus to fully safely function at voltages below 20V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"markdown-heading\" dir=\"auto\"\u003e\n\u003ch3 dir=\"auto\" tabindex=\"-1\"\u003eAC Current Monitoring\u003c\/h3\u003e\n\u003cp\u003eAC Mains Current on the \u003cstrong\u003eIPEM Plus\u003c\/strong\u003e, is safely monitored using an inductive non-direct connection method.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIPEM Plus\u003c\/strong\u003e has selectable inputs to be able to use either:\u003c\/p\u003e\n\u003cdiv class=\"markdown-heading\"\u003e\n\u003cul\u003e\n\u003cli class=\"heading-element\"\u003e\n\u003cstrong\u003eCT (Current Transformer) \u003c\/strong\u003e- Home and Office\n\u003cul\u003e\n\u003cli class=\"heading-element\"\u003eThis typically is by using a CT (Current Transformer), Current Clamp which can measure up to around 100A. This normally is a split core, such as using the popular YHDC SCT-013 100A-50mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"markdown-heading\"\u003e\n\u003cul\u003e\n\u003cli class=\"heading-element\"\u003e\n\u003cstrong\u003eSplit core current transformers, or Rogowski\u003c\/strong\u003e - Commercial and Industrial\n\u003cul\u003e\n\u003cli class=\"heading-element\"\u003eFor for larger solar farms, commercial and industrial currents, heavy duty split core current transformers, or Rogowski.\u003c\/li\u003e\n\u003cli class=\"heading-element\"\u003eThe advantages of Rogowski coils, is that that are flexible air-core sensors, providing a wider, non-saturating range, ease of installation, and excellent high-frequency response.6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eFurther information in \u003ca href=\"https:\/\/github.com\/DitroniX\/IPEM-Plus-ESP32-C5-LoRa-LoRaWAN-IoT-Mains-Power-Energy-Monitor\/wiki\/AC-Current-and-Power-Monitoring\" rel=\"noopener\" target=\"_blank\"\u003eCurrent Monitoring can be found here\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 class=\"heading-element\" dir=\"auto\" tabindex=\"-1\"\u003eAC Voltage Monitoring\u003c\/h3\u003e\n\u003cp\u003eAll AC Mains is safely and galvanically isolated using a low voltage transformer. Examples are bell transformers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"markdown-heading\" dir=\"auto\"\u003e\n\u003ch5 class=\"heading-element\" dir=\"auto\" tabindex=\"-1\"\u003eSupports AC Monitoring Around The \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/Mains_electricity_by_country\" rel=\"nofollow\"\u003eWorld\u003c\/a\u003e\n\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eEurope and UK\u003c\/strong\u003e which typically is 230 V @ 50 Hz\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003eWith ranges around 216 V to 253 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eUSA and Canada\u003c\/strong\u003e which typically is 120 V or 230 V @ 60 Hz\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003eWith ranges around 114 V to 126 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eJapan\u003c\/strong\u003e which typically is 100 V @ 50 Hz or 60 Hz\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003eEastern Japan is 50 Hz, and Western Japan is 60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eWorld\u003c\/strong\u003e typically is 220V-240 V @ 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFurther information in \u003ca href=\"https:\/\/github.com\/DitroniX\/IPEM-Plus-ESP32-C5-LoRa-LoRaWAN-IoT-Mains-Power-Energy-Monitor\/wiki\/AC-Mains-Voltage-Sense-Input\" rel=\"noopener\" target=\"_blank\"\u003eAC Voltage Monitoring can be found here\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"markdown-heading\" dir=\"auto\"\u003e\n\u003cdiv class=\"markdown-heading\" dir=\"auto\"\u003e\n\u003ch3 class=\"heading-element\" dir=\"auto\" tabindex=\"-1\"\u003eLoRa Long Range IoT Data Radio Integration\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eIn addition, to compliment the powerful C5 radio, the \u003cstrong\u003eIPEM Plus\u003c\/strong\u003e has an onboard LoRa SX1262 Transceiver Radio.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis allows \u003cstrong\u003eIPEM Plus\u003c\/strong\u003e to be also used on remote Power Energy Monitoring projects, using the integrated \u003ca href=\"https:\/\/github.com\/DitroniX\/IPEM-Plus-ESP32-C5-LoRa-LoRaWAN-IoT-Mains-Power-Energy-Monitor\/wiki\/Lora-Topology-Overview\"\u003eLoRa and LoRaWan\u003c\/a\u003e long range wireless network. This includes networks such as \u003ca href=\"https:\/\/www.thethingsnetwork.org\/\" rel=\"nofollow\"\u003eTTN\u003c\/a\u003e, \u003ca href=\"https:\/\/meshtastic.org\/\" rel=\"nofollow\"\u003eMeshtastic\u003c\/a\u003e, \u003ca href=\"https:\/\/www.helium.com\/iot\" rel=\"nofollow\"\u003eHelium\u003c\/a\u003e and \u003ca href=\"https:\/\/www.chirpstack.io\/\" rel=\"nofollow\"\u003eChirpStack\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe LoRa radio module operates from 850 MHz through to 930 MHz, so providing worldwide capability. This uses the LoRa module E22-900M22S, incorporating the Semtech SX1262.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eExample \u003ca href=\"https:\/\/www.thethingsnetwork.org\/docs\/lorawan\/frequencies-by-country\/\" rel=\"nofollow\"\u003ebands\u003c\/a\u003e:\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003eAS923 (AS1) band (920-923 MHz) in Japan, Malaysia, Singapore\u003c\/li\u003e\n\u003cli\u003eAS923 (AS2) band (915–928 MHz) in Asia\u003c\/li\u003e\n\u003cli\u003eAU915 band (915–928 MHz) in South America\u003c\/li\u003e\n\u003cli\u003eCN779 band (779-787 MHz) in China\u003c\/li\u003e\n\u003cli\u003eEU868 band (863–870 MHz) in Europe\u003c\/li\u003e\n\u003cli\u003eIN865 band (865-867 MHz) in India\u003c\/li\u003e\n\u003cli\u003eKR920 band (920-923 MHz) in Korea\u003c\/li\u003e\n\u003cli\u003eRU864 band (864-870 MHz) in Russia\u003c\/li\u003e\n\u003cli\u003eUS915 band (902–928 MHz) in North America\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"markdown-heading\" dir=\"auto\"\u003e\n\u003ch3 class=\"heading-element\" dir=\"auto\" tabindex=\"-1\"\u003eLoRa Long Satellite IoT\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eIPEM Plus LoRa Wireless includes the expanded Satellite IoT range, \u003c\/strong\u003eenabling direct-to-satellite IoT connectivity, with suitable installation antenna.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay User Panel\u003c\/li\u003e\n\u003cli\u003eDIN Enclosure\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DitroniX","offers":[{"title":"Default Title","offer_id":53391133245768,"sku":"IPEM-Plus-ESP32C5-LoRa","price":55.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/8507\/9368\/files\/ipem-plus-atm90e36-esp32c5-sx1262-lora-wi-fi-iot-remote-mains-power-energy-monitor-6176612.png?v=1782753809","url":"https:\/\/ditronix.net\/products\/ipem-plus-atm90e36-esp32c5-sx1262-lora-wi-fi-iot-remote-mains-power-energy-monitor","provider":"DitroniX","version":"1.0","type":"link"}